All is okay | 显示正常 |
Pulse inhibit | 脉冲禁止,逆变器在关闭状态 |
Rdy to switch on | 等待启动状态 |
Speed control | 速度启动模式 |
Posit. control | 外部控制模式 |
Analogue mode | 模拟控制模式,模拟给的输出 |
显示 | 说明 | 处理建议 |
BB off (instantly after switching power on ) |
开关电源瞬间有短路 | 查看x3编码器接口是否电压短路 拔掉热敏电阻,或主电源接触不良 外部故障有短路 |
BB instantly off (after ISP and E0) |
启动中电源关闭 | 电机接线短路,接触器故障 编码器线和外壳短路 |
BB off after a few seconds | 启动几秒钟跳闸 | 马达旋转错误或编码器故障 电机短路或过载 刹车盘未放开 |
Motor is rotating very slow or is jerking |
电机旋转很慢或震动 | 编码器连接错误或设置参数错误 |
Motor causes heavy noise ('growling') |
电机噪音过大或震动 | 参数设定错误 编码器屏蔽线是否正确 输出不平衡 |
extraneous voltage 24V short-circuited |
启动供电+24v短路 | X1/x2外边断开看是否正常 |
Parameter can not be modified |
参数锁定 | 参数或安全开关锁定了 |
After changing data the drive does not work |
参数从错误 | 参数错误,恢复出厂或重新设置 |
After changing the software the drive does not work |
软件错误或不匹配 | 软件恢复或版本错误 |
Motor is accelerating very slow |
加速很慢 | t组参数错误 F0参数错误 |
Motor oscillates during constant motion | 震动曲线错误 | 重新设定参数 |
Motor jerks heavy during the start-up process |
启动转矩不足 | 排除机械故障可能 重新设定参数 |
Motor jerks heavy during the approach |
电机重载时转矩不足 | 起重过载 参数设置不正确 软件版本是否正确 |
Synchronous gearless does not run correctly |
无法同步运行 | 如编码器报警,确认编码器连接正确 屏蔽是否完好 |
In spite of 'BB' on there is no connection to the PC |
变频器无法连接电脑 | 检查特殊(变频器-pc)连接线 参数设定错误 连接口com1选择错误 |
显示 | 说明 | 建议处理 |
"Rot. encoder err" | 编码器故障 | 没有连接编码器 编码器类型设定错误 编码器接线错误 |
"IIDT" | 输出过电流 | 过载,负载过大 电机短路或过温 编码器故障 变频器模块故障 |
"Phase failure" | 输入缺相 | 输入缺相 母线电压过低 相电路检测电路故障 |
"DC link over V" | 过电压 | 输入电压不稳定或电压过高 变频器检测电路发生故障 |
"DC link under V" | 欠电压 | 输入电压不稳定或电压过低 变频器检测电路发生故障 |
"Temp rectifier" | 过温 | 散热器温度过高 风机坏,或散热翅片堵塞 温度传感器故障或温升电路坏 |
"PTC therm. error" | 马达温度过高 | 马达过载时间长或轻微短路 马达风扇坏 马达检测探讨故障或检测电路坏 |
"Short circuit" | 输出短路 | 输出故障或电缆短路 变频器功率组件坏 变频器检测组件坏 |
"Parameter error" | 参数错误 | 检查控制板硬件存储是否正常 参数设置错误 |
"RS485" | 通讯故障 | 控制板和逆变之间的通讯有故障 |