8: boot sequence failed or flash prom empty 启动顺序错误或闪存数据丢失
f81: auxiliary voltage below 90v 辅助电压低于90V
f82: hardware fault 硬件故障
f83: software fault 软件故障
f84: par flash read fault (e g che cksum wrong) 闪存校验错误故障(例如澈校验和错误)
f85: compatibility fault (software or typecode not compatible to parameters) 兼容性故障(软件或参数写入出错出现不兼容的故障)
f86: typecode read fault (checksum failure during typecode check) 类型代码读取失败故障(类型代码检查过程中校验失败)
f88: mains voltage smaller 40vac 主电源电源电压小于40VAC
f89: mains voltage higher 620vac 主电源电压高于620vac
f90: mains sync fault (e.g. f<40hz f>70hz) 电源同步故障(例如电源输入频率小于F<40HZ或大于 F>70HZ)
f91: field current above 125% of selected current measurement range. 励磁选择的输出电流超出测量范围的125%以上。
f92: fast voltage rise scc parameters (dcs500b=p13.10 p13.07 dcs600=p44.04 p44.10 dcs800=pxx.xx pxx .xx) 励磁输出电压过高故障,(查看SCC的参数设置)(dcs500b= p13.10 p13.07 DCS600= p44.04 p44.10 DCS800= pxx.xx PXX.XX)
alarm(A报警查询)
a81: parameters added 添加的参数错误
a88: up/download failed 上/下载失败报警
a90: compatibility alarm 兼容性报警
a91: parameter restored 参数恢复报警
说明:通过串行连接的电枢变流器接收到的所有故障,和报警显示在dcf503b dcf504b的七段显示器上